Kenmore Elite Dryer Won’T Start

Blown Thermal Fuse

The thermal fuse, also known as a safety cutoff fuse, is located in the dryer and is responsible for shutting the machine off if there is an overheating issue. An overheating issue might be caused by worn-out elements or a clogged vent, preventing the dryer from properly cooling down.

Sometimes, the thermal fuse will be located inside of your dryer. This is to protect the heating element from overheating. There will be a problem with your dryer if there is a melting of the fuse or if it has been damaged. You can check the fuse by unplugging the dryer and visually inspecting it. If there is any damage, you need to replace it before using the dryer again.

To test the fuse, you will need to open the case on the dryer. There should be a wire that runs from the heating element to a thermal fuse. The wire may be connected with a black electrical tape and will be a little smaller than most wires. When the wire has continuity, then the thermal fuse is working fine. If there is no continuity, then the thermal fuse has blown and needs to be replaced.

With an air restriction, you need to take measures as soon as possible. For example, you can clean your dryer and check the vents for any blocking or obstructions that may be causing air restriction. If you find any of them, then you should remove it immediately.

Incorrect Dryer Settings

It’s possible that the Kenmore dryer is lit up but won’t start, but before you dive into troubleshooting, check your settings. As with any appliance or home device, something as simple as selecting the correct settings for your load can save you time and help prevent problems. When it comes to troubleshooting your Kenmore dryer, make sure the settings are correct. Setting the wrong dryer setting can result in a long wait for a laundry load to complete or it not starting at all.

With the control lock feature, you can lock the dryer’s control panel so that it is not possible to start or stop the dryer. Conversely, with the delay start function, you can delay the beginning of a making cycle. This will give you more time to prepare clothing or accessories and ensure that clothing is properly dried without wrinkles or creases. You need to disable both of these settings.

The door switch activates when the dryer door is closed. On most dryers, the door switch makes an audible clicking sound when it activates. To determine if the door switch is working, try starting your dryer and then listen for the “click.” If the door switch makes a clicking sound, it is probably not defective. If you don’t hear a click, use a multimeter to use the door switch for continuity. If the switch does not have continuity, replace it.

The thermal fuse is a safety device designed to protect the dryer from overheating. The fuse is located on the blower housing or at the dryer’s heat source such as the heating element on electric dryers or at the burner on gas models. The fuse should be closed for continuity meaning it has a continuous electrical path through it when good. If overheated the fuse will have no continuity meaning the electrical path is broken and the fuse has blown out. A multimeter can be used to test it for continuity. Be aware that a blown thermal fuse is an indication of a restricted exhaust vent from the dryer to the outside. Always check the dryer venting when replacing a blown thermal fuse.

To determine if the start switch is defective, attempt to start the dryer. If the dryer hums but does not start, the start switch is not at fault. If the dryer does not respond or make any noise, the start switch could be at fault. Use a multimeter to test the start switch for continuity. If the switch does not have continuity, replace it.

FAQ

Why is my Kenmore Elite dryer not starting?

If the dryer hums but does not start, the start switch is not at fault. If the dryer does not respond or make any noise, the start switch could be at fault. Use a multimeter to test the start switch for continuity. If the switch does not have continuity, replace it.

Why won’t my dryer start all of a sudden?

If the dryer start switch does not have continuity when it is activated, it will need to be replaced. The door switch is located near the dryer door and is activated when the door is closed. If the door switch fails, the dryer won’t start at all. Most door switches will make an audible click when they are activated.

How do you reset a Kenmore Elite front load dryer?

There are many things that could be the culprit for why your dryer won’t start, including a bad thermal fuse; a failed start switch or door switch; a bad drive motor (what makes the dryer’s drum turn and the blower wheel to work); a broken drive belt; a bad timer; a bad belt switch; a blown control board; or overall …